Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device Text with EEA relevance
- 1.1.The information referred to in Article 4(1)(b) shall be provided in the following order:
- (a) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of Annex VII;
- (b) the water heating energy efficiency class of the model, under average climate conditions, in accordance with point 1 of Annex II;
- (c) the water heating energy efficiency in %, under average climate conditions, rounded to the nearest integer and calculated in accordance with point 3 of Annex VIII;
- (d) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, under average climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII;
- (e) the sound power level, indoors, in dB, rounded to the nearest integer (for heat pump water heaters, if applicable);
- in addition, for solar water heaters and heat pump water heaters:
- (f) the water heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 3 of Annex VIII;
- (g) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, under colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII;
- in addition, for solar water heaters:
- (h) the collector aperture area in m2, to two decimal places;
- (i) the storage volume in litres, rounded to the nearest integer;
- in addition, for heat pump water heaters:
- (j) the sound power level, outdoors, in dB, rounded to the nearest integer.
- 1.2.Where other information contained in the product fiche is also provided, it shall be in the form and order specified in point 1 of Annex IV.
- 1.3.The size and font in which the information referred in points 1.1 and 1.2 is printed or shown shall be legible.
2. HOT WATER STORAGE TANKS
- 2.1.The information referred to in Article 4(2)(b) shall be provided in the following order:
- (a) the energy efficiency class of the model, determined in accordance with point 2 of Annex II;
- (b) the standing loss in W, rounded to the nearest integer;
- (c) the storage volume in litres, rounded to the nearest integer.
- 2.2.The size and font in which the information referred in point 2.1 is printed or shown shall be legible.
3. PACKAGES OF WATER HEATER AND SOLAR DEVICE
- 3.1.The information referred to in Article 4(3)(b) shall be provided in the following order:
- (a) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II;
- (b) the water heating energy efficiency in %, rounded to the nearest integer;
- (c) the elements set out in Figure 1 of Annex IV.
- 3.2.The size and font in which the information referred in point 3.1 is printed or shown shall be legible.
ANNEX VII
Measurements
-
- For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union, or using other reliable, accurate and reproducible measurement methods that take into account the generally recognised state-of-the-art methods. They shall meet the conditions and technical parameters set out in points 2 to 9.
-
- General conditions for testing water heaters:
- (a) measurements shall be carried out using the load profiles set out in Table 3;
- (b) measurements shall be carried out using a 24-hour measurement cycle as follows:
- — 00:00 to 06:59: no water draw-off,
- — from 07:00: water draw-offs according to the declared load profile,
- — from end of last water draw-off until 24:00: no water draw-off;
- (c) the declared load profile shall be the maximum load profile or the load profile one below the maximum load profile.
Table 3
Load profiles of water heaters
| h | 3XS | 3XS | 3XS | XXS | XXS | XXS | XS | XS | XS | S | S | S | S |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| h | Qtap | f | Tm | Qtap | f | Tm | Qtap | f | Tm | Qtap | f | Tm | Tp |
| h | kWh | l/min | °C | kWh | l/min | °C | kWh | l/min | °C | kWh | l/min | °C | °C |
| 07:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
| 07:05 | 0,015 | 2 | 25 | ||||||||||
| 07:15 | 0,015 | 2 | 25 | ||||||||||
| 07:26 | 0,015 | 2 | 25 | ||||||||||
| 07:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,525 | 3 | 35 | 0,105 | 3 | 25 | |
| 07:45 | |||||||||||||
| 08:01 | |||||||||||||
| 08:05 | |||||||||||||
| 08:15 | |||||||||||||
| 08:25 | |||||||||||||
| 08:30 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | |||||||
| 08:45 | |||||||||||||
| 09:00 | 0,015 | 2 | 25 | ||||||||||
| 09:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
| 10:00 | |||||||||||||
| 10:30 | |||||||||||||
| 11:00 | |||||||||||||
| 11:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
| 11:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
| 12:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 12:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 12:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,525 | 3 | 35 | 0,315 | 4 | 10 | 55 |
| 14:30 | 0,015 | 2 | 25 | ||||||||||
| 15:00 | 0,015 | 2 | 25 | ||||||||||
| 15:30 | 0,015 | 2 | 25 | ||||||||||
| 16:00 | 0,015 | 2 | 25 | ||||||||||
| 16:30 | |||||||||||||
| 17:00 | |||||||||||||
| 18:00 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | |||||||
| 18:15 | 0,105 | 2 | 25 | 0,105 | 3 | 40 | |||||||
| 18:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 19:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 19:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 20:00 | 0,105 | 2 | 25 | ||||||||||
| 20:30 | 1,05 | 3 | 35 | 0,42 | 4 | 10 | 55 | ||||||
| 20:45 | 0,105 | 2 | 25 | ||||||||||
| 20:46 | |||||||||||||
| 21:00 | 0,105 | 2 | 25 | ||||||||||
| 21:15 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 21:30 | 0,015 | 2 | 25 | 0,525 | 5 | 45 | |||||||
| 21:35 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| 21:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
| Qref | 0,345 | 0,345 | 0,345 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 | 2,100 |
Continued Table 3
Load profiles of water heaters
| h | M | M | M | M | L | L | L | L | XL | XL | XL | XL |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| h | Qtap | f | Tm | Tp | Qtap | f | Tm | Tp | Qtap | f | Tm | Tp |
| h | kWh | l/min | °C | °C | kWh | l/min | °C | °C | kWh | l/min | °C | °C |
| 07:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 07:05 | 1,4 | 6 | 40 | 1,4 | 6 | 40 | ||||||
| 07:15 | 1,82 | 6 | 40 | |||||||||
| 07:26 | 0,105 | 3 | 25 | |||||||||
| 07:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
| 07:45 | 0,105 | 3 | 25 | 4,42 | 10 | 10 | 40 | |||||
| 08:01 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
| 08:05 | 3,605 | 10 | 10 | 40 | ||||||||
| 08:15 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
| 08:25 | 0,105 | 3 | 25 | |||||||||
| 08:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 08:45 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 09:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 09:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 10:00 | 0,105 | 3 | 25 | |||||||||
| 10:30 | 0,105 | 3 | 10 | 40 | 0,105 | 3 | 10 | 40 | 0,105 | 3 | 10 | 40 |
| 11:00 | 0,105 | 3 | 25 | |||||||||
| 11:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 11:45 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 12:00 | ||||||||||||
| 12:30 | ||||||||||||
| 12:45 | 0,315 | 4 | 10 | 55 | 0,315 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 |
| 14:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 15:00 | 0,105 | 3 | 25 | |||||||||
| 15:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 16:00 | 0,105 | 3 | 25 | |||||||||
| 16:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 17:00 | 0,105 | 3 | 25 | |||||||||
| 18:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 18:15 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | |||
| 18:30 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | |||
| 19:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
| 19:30 | ||||||||||||
| 20:00 | ||||||||||||
| 20:30 | 0,735 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 |
| 20:45 | ||||||||||||
| 20:46 | 4,42 | 10 | 10 | 40 | ||||||||
| 21:00 | 3,605 | 10 | 10 | 40 | ||||||||
| 21:15 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
| 21:30 | 1,4 | 6 | 40 | 0,105 | 3 | 25 | 4,42 | 10 | 10 | 40 | ||
| 21:35 | ||||||||||||
| 21:45 | ||||||||||||
| Qref | 5,845 | 5,845 | 5,845 | 5,845 | 11,655 | 11,655 | 11,655 | 11,655 | 19,07 | 19,07 | 19,07 | 19,07 |
Continued Table 3
Load profiles of water heaters
| h | XXL | XXL | XXL | XXL |
|---|---|---|---|---|
| h | Qtap | f | Tm | Tp |
| h | kWh | l/min | °C | °C |
| 07:00 | 0,105 | 3 | 25 | |
| 07:05 | ||||
| 07:15 | 1,82 | 6 | 40 | |
| 07:26 | 0,105 | 3 | 25 | |
| 07:30 | ||||
| 07:45 | 6,24 | 16 | 10 | 40 |
| 08:01 | 0,105 | 3 | 25 | |
| 08:05 | ||||
| 08:15 | 0,105 | 3 | 25 | |
| 08:25 | ||||
| 08:30 | 0,105 | 3 | 25 | |
| 08:45 | 0,105 | 3 | 25 | |
| 09:00 | 0,105 | 3 | 25 | |
| 09:30 | 0,105 | 3 | 25 | |
| 10:00 | 0,105 | 3 | 25 | |
| 10:30 | 0,105 | 3 | 10 | 40 |
| 11:00 | 0,105 | 3 | 25 | |
| 11:30 | 0,105 | 3 | 25 | |
| 11:45 | 0,105 | 3 | 25 | |
| 12:00 | ||||
| 12:30 | ||||
| 12:45 | 0,735 | 4 | 10 | 55 |
| 14:30 | 0,105 | 3 | 25 | |
| 15:00 | 0,105 | 3 | 25 | |
| 15:30 | 0,105 | 3 | 25 | |
| 16:00 | 0,105 | 3 | 25 | |
| 16:30 | 0,105 | 3 | 25 | |
| 17:00 | 0,105 | 3 | 25 | |
| 18:00 | 0,105 | 3 | 25 | |
| 18:15 | 0,105 | 3 | 40 | |
| 18:30 | 0,105 | 3 | 40 | |
| 19:00 | 0,105 | 3 | 25 | |
| 19:30 | ||||
| 20:00 | ||||
| 20:30 | 0,735 | 4 | 10 | 55 |
| 20:45 | ||||
| 20:46 | 6,24 | 16 | 10 | 40 |
| 21:00 | ||||
| 21:15 | 0,105 | 3 | 25 | |
| 21:30 | 6,24 | 16 | 10 | 40 |
| 21:35 | ||||
| 21:45 | ||||
| Qref | 24,53 | 24,53 | 24,53 | 24,53 |
-
- Conditions for testing the smart control compliance (smart) of water heaters
Where the supplier deems it appropriate to declare the value of smart as being ‘1’, measurements of the weekly electricity and/or fuel consumption with smart controls and the weekly electricity and/or fuel consumption without smart controls shall be carried out using a two-week measurement cycle as follows:
- — days 1 to 5: random sequence of load profiles chosen from the declared load profile and the load profile one below the declared load profile, and smart control disabled,
- — days 6 and 7: no water draw-offs, and smart control disabled,
- — days 8 to 12: repetition of the same sequence applied for days 1 to 5, and smart control enabled,
- — days 13 and 14: no water draw-offs, and smart control enabled,
- — the difference between the useful energy content measured during days 1 to 7 and the useful energy content measured during days 8 to 14 shall not exceed 2 % of Qref of the declared load profile.
-
- Conditions for testing solar water heaters
The solar collector, solar hot water storage tank, pump in the collector loop (if applicable) and heat generator shall be tested separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be tested in combination. The heat generator shall be tested under the conditions set out in point 2 of this Annex.
The results shall be used for the calculations set out in point 3(b) of Annex VIII under the conditions set out in Tables 4 and 5. For the purpose of establishing Qtota the efficiency of the heat generator using the Joule effect in electric resistance heating elements is assumed to be 100/CC, expressed in %.
-
- Conditions for testing heat pump water heaters
- — Heat pump water heaters shall be tested under the conditions set out in Table 6,
- — Heat pump water heaters which use ventilation exhaust air as the heat source shall be tested under the conditions set out in Table 7.
-
- Conditions for testing solar devices
The solar collector, solar hot water storage tank and pump in the collector loop (if applicable) shall be tested separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be tested in combination.
The results shall be used for the calculations of Qnonsol for the load profiles M, L, XL and XXL under the average climate conditions set out in Tables 4 and 5 and Qaux.
Table 4
Average daytime temperature [°C]
| January | February | March | April | May | June | July | August | September | October | November | December | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Average climate conditions | + 2,8 | + 2,6 | + 7,4 | + 12,2 | + 16,3 | + 19,8 | + 21,0 | + 22,0 | + 17,0 | + 11,9 | + 5,6 | + 3,2 |
| Colder climate conditions | – 3,8 | – 4,1 | – 0,6 | + 5,2 | + 11,0 | + 16,5 | + 19,3 | + 18,4 | + 12,8 | + 6,7 | + 1,2 | – 3,5 |
| Warmer climate conditions | + 9,5 | + 10,1 | + 11,6 | + 15,3 | + 21,4 | + 26,5 | + 28,8 | + 27,9 | + 23,6 | + 19,0 | + 14,5 | + 10,4 |
Table 5
Average global solar irradiance [W/m2]
| January | February | March | April | May | June | July | August | September | October | November | December | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Average climate conditions | 70 | 104 | 149 | 192 | 221 | 222 | 232 | 217 | 176 | 129 | 80 | 56 |
| Colder climate conditions | 22 | 75 | 124 | 192 | 234 | 237 | 238 | 181 | 120 | 64 | 23 | 13 |
| Warmer climate conditions | 128 | 137 | 182 | 227 | 248 | 268 | 268 | 263 | 243 | 175 | 126 | 109 |
Table 6
Standard rating conditions for heat pump water heaters, temperatures in dry bulb air temperature (wet bulb air temperature in brackets)
| Heat source | Outdoor air | Outdoor air | Outdoor air | Indoor air | Exhaust air | Brine | Water |
|---|---|---|---|---|---|---|---|
| Climate conditions | Average climate conditions | Colder climate conditions | Warmer climate conditions | Not applicable | All climate conditions | All climate conditions | All climate conditions |
| Temperature | + 7 °C (+ 6 °C) | + 2 °C (+ 1 °C) | + 14 °C (+ 13 °C) | + 20 °C (maximum + 15 °C) | + 20 °C (+ 12 °C) | 0 °C (inlet)/– 3 °C (outlet) | + 10 °C (inlet)/+ 7 °C (outlet) |
Table 7
Maximum ventilation exhaust air available [m3/h], at a temperature of 20 °C and with humidity of 5,5 g/m3
| Declared load profile | XXS | XS | S | M | L | XL | XXL |
|---|---|---|---|---|---|---|---|
| Maximum ventilation exhaust air available | 109 | 128 | 128 | 159 | 190 | 870 | 1 021 |
-
- Technical parameters of water heaters
The following parameters shall be established for water heaters:
- (a) the daily electricity consumption Qelec in kWh, rounded to three decimal places;
- (b) the declared load profile, expressed by the appropriate letter in accordance with Table 3 of this Annex;
- (c) the sound power level in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable);
in addition, for water heaters using fossil and/or biomass fuels:
- (d) the daily fuel consumption Qfuel in kWh in terms of GCV, rounded to three decimal places;
in addition, for water heaters for which the value of smart is declared as being ‘1’:
- (e) the weekly fuel consumption with smart controls Qfuel,week,smart in kWh in terms of GCV, rounded to three decimal places;
- (f) the weekly electricity consumption with smart controls Qelec,week,smart in kWh, rounded to three decimal places;
- (g) the weekly fuel consumption without smart controls Qfuel,week in kWh in terms of GCV, rounded to three decimal places;
- (h) the weekly electricity consumption without smart controls Qelec,week in kWh, rounded to three decimal places;
in addition, for solar water heaters:
- (i) the collector aperture area Asol in m2, rounded to two decimal places;
- (j) the zero-loss efficiency η0, rounded to three decimal places;
- (k) the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;
- (l) the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;
- (m) the incidence angle modifier IAM, rounded to two decimal places;
- (n) the pump power consumption solpump in W, rounded to two decimal places;
- (o) the standby power consumption solstandby in W, rounded to two decimal places;
in addition, for heat pump water heaters:
- (p) the sound power level LWA in dB, outdoors, rounded to the nearest integer.
-
- Technical parameters of hot water storage tanks
The following parameters shall be established for hot water storage tanks:
- (a) the storage volume V in litres, rounded to one decimal place;
- (b) the standing loss S in W, rounded to one decimal place.
-
- Technical parameters of solar devices
The following parameters shall be established for solar devices:
- (a) the collector aperture area Asol in m2, rounded to two decimal places;
- (b) the zero-loss efficiency η0, rounded to three decimal places;
- (c) the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;
- (d) the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;
- (e) the incidence angle modifier IAM, rounded to two decimal place;
- (f) the pump power consumption solpump in W, rounded to two decimal places;
- (g) the standby power consumption, solstandby in W, rounded to two decimal places.
ANNEX VIII
Method for calculating the water heating energy efficiency of water heaters
-
- For the purposes of compliance and verification of compliance with the requirements of this Regulation, calculations shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union, or using other appropriate calculation methods that take into account the generally recognised state-of-the-art methods. They shall meet the technical parameters and calculations set out in points 2 to 6.
Technical parameters used for the calculations shall be measured in accordance with Annex VII.
-
- Technical parameters of water heaters
The following parameters shall be calculated for water heaters under average climate conditions:
- (a) the water heating energy efficiency ηwh in %, rounded to one decimal place;
- (b) the annual electricity consumption AEC in kWh in terms of final energy, rounded to the nearest integer;
in addition, for water heaters using fuels under average climate conditions:
- (c) the annual fuel consumption AFC in kWh in terms of GCV, rounded to the nearest integer;
in addition, for solar water heaters under average climate conditions:
- (d) the heat generator water heating energy efficiency ηwh,nonsol in %, rounded to one decimal place;
- (e) the annual auxiliary electricity consumption Qaux in kWh in terms of final energy, rounded to one decimal place;
in addition, for solar water heaters and heat pump water heaters under colder and warmer climate conditions:
- (f) the parameters set out in points (a) to (c);
in addition for solar water heaters under average, colder and warmer climate conditions:
- (g) the annual non-solar heat contribution Qnonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, rounded to one decimal place.
-
- Calculation of the water heating energy efficiency ηwh
- (a)Conventional water heaters and heat pump water heaters:
- The water heating energy efficiency is calculated as follows:
Image omitted; see official source
- For water-/brine-to-water heat pump water heaters, the electricity consumption of one or more ground water pumps shall be taken into account.
- (b)Solar water heaters:
- The water heating energy efficiency is calculated as follows:
Image omitted; see official source
- Where:
Image omitted; see official source
-
- Calculation of the annual electricity consumption AEC and the annual fuel consumption AFC
- (a)Conventional water heaters and heat pump water heaters:
- The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
Image omitted; see official source
- The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
Image omitted; see official source
- (b)Solar water heaters:
- The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
Image omitted; see official source
- The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
Image omitted; see official source
-
- Determination of the smart control factor SCF and of smart control compliance smart
- (a)The smart control factor is calculated as follows:
Image omitted; see official source
- (b)If SCF ≥ 0,07, the value of smart shall be 1. In all other cases, the value of smart shall be 0.
-
- Determination of the ambient correction term Qcor
The ambient correction term is calculated as follows:
- (a) for conventional water heaters using electricity: Image omitted; see official source
- (b) for conventional water heaters using fuels: Image omitted; see official source
- (c) for heat pump water heaters: Image omitted; see official source
Where:
the k-values are given in Table 8 for each load profile.
Table 8
k-values
| 3XS | XXS | XS | S | M | L | XL | XXL | |
|---|---|---|---|---|---|---|---|---|
| k | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,0 |
ANNEX IX
Product compliance verification by market surveillance authorities
The verification tolerances set out in this Annex relate only to the verification of the measured parameters by Member State authorities and shall not be used by the supplier as an allowed tolerance to establish the values in the technical documentation. The values and classes on the label or in the product fiche shall not be more favourable for the supplier than the values reported in the technical documentation.
When verifying the compliance of a product model with the requirements laid down in this Delegated Regulation, for the requirements referred to in this Annex, the authorities of the Member States shall apply the following procedure:
- (1) The Member State authorities shall verify one single unit of the model.
- (2) The model shall be considered to comply with the applicable requirements if:
- (a) the values given in the technical documentation pursuant to Article 5(b) of Directive 2010/30/EU (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the supplier than the corresponding values given in the test reports pursuant to point (iii) of the abovementioned Article; and
- (b) the values published on the label and in the product fiche are not more favourable for the supplier than the declared values, and the indicated energy efficiency class is not more favourable for the supplier than the class determined by the declared values; and
- (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in Table 9.
- (3) If the results referred to in points 2(a) or (b) are not achieved, the model and all other equivalent water heater models, hot water storage tanks models, solar device models or package of water heater and solar device models shall be considered not to comply with this Delegated Regulation.
- (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be of one or more different equivalent models.
- (5) The model shall be considered to comply with the applicable requirements if for these three units, the arithmetical mean of the determined values complies with the respective tolerances given in Table 9.
- (6) If the result referred to in point 5 is not achieved, the model and all other equivalent water heater models, hot water storage tanks models, solar device models or package of water heater and solar device models shall be considered not to comply with this Delegated Regulation.
- (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
The Member State authorities shall use the measurement and calculation methods set out in Annex VII and Annex VIII.
The Member State authorities shall only apply the verification tolerances that are set out in Table 9 and shall only use the procedure described in points 1 to 7 for the requirements referred to in this Annex. No other tolerances, such as those set out in harmonised standards or in any other measurement method, shall be applied.
Table 9
Verification tolerances
| Parameters | Verification tolerances |
|---|---|
| Daily electricity consumption, Qelec | The determined value shall not exceed the declared value by more than 5 %. |
| Sound power level, LWA, indoors and/or outdoors | The determined value shall not exceed the declared value by more than 2 dB. |
| Daily fuel consumption, Qfuel | The determined value shall not exceed the declared value by more than 5 %. |
| Weekly fuel consumption with smart controls, Qfuel,week,smart | The determined value shall not exceed the declared value by more than 5 %. |
| Weekly electricity consumption with smart controls, Qelec,week,smart | The determined value shall not exceed the declared value by more than 5 %. |
| Weekly fuel consumption without smart controls, Qfuel,week | The determined value shall not exceed the declared value by more than 5 %. |
| Weekly electricity consumption without smart controls, Qelec,week | The determined value shall not exceed the declared value by more than 5 %. |
| Storage volume, V | The determined value shall not be lower than the declared value by more than 2 %. |
| Collector aperture area, Asol | The determined value shall not be lower than the declared value by more than 2 %. |
| Pump power consumption, solpump | The determined value shall not exceed the declared value by more than 3 %. |
| Standby power consumption, solstandby | The determined value shall not exceed the declared value by more than 5 %. |
| Standing loss, S | The determined value shall not exceed the declared value by more than 5 %. |
ANNEX X
Information to be provided in the case of sale, hire or hire-purchase through the internet
- (1)For the purpose of points 2 to 5 of this Annex the following definitions shall apply:
- (a) ‘display mechanism’ means any screen, including tactile screen, or other visual technology used for displaying internet content to users;
- (b) ‘nested display’ means visual interface where an image or data set is accessed by a mouse click, mouse roll-over or tactile screen expansion of another image or data set;
- (c) ‘tactile screen’ means a screen responding to touch, such as that of a tablet computer, slate computer or a smartphone;
- (d) ‘alternative text’ means text provided as an alternative to a graphic allowing information to be presented in non-graphical form where display devices cannot render the graphic or as an aid to accessibility such as input to voice synthesis applications.
- (2)The appropriate label made available by suppliers in accordance with Article 3 or in the case of a package where appropriate duly filled in based on the label and fiches provided by suppliers in accordance with Article 3, shall be shown on the display mechanism in proximity to the price of the product or package in accordance with the timetable set out in Article 3. If both a product and a package are shown, but with a price indicated only for the package, only the package label shall be displayed. The size shall be such that the label is clearly visible and legible and shall be proportionate to the size specified in Annex III. The label may be displayed using a nested display, in which case the image used for accessing the label shall comply with the specifications laid down in point 3 of this Annex. If nested display is applied, the label shall appear on the first mouse click, mouse roll-over or tactile screen expansion on the image.
- (3)The image used for accessing the label in the case of nested display shall:
- (a) be an arrow in the colour corresponding to the energy efficiency class of the product or package on the label;
- (b) indicate on the arrow the energy efficiency class of the product or package in white in a font size equivalent to that of the price; and
- (c) have one of the following two formats: Image omitted; see official source
- (4)In the case of nested display, the sequence of display of the label shall be as follows:
- (a) the image referred to in point 3 of this Annex shall be shown on the display mechanism in proximity to the price of the product or package;
- (b) the image shall link to the label;
- (c) the label shall be displayed after a mouse click, mouse roll-over or tactile screen expansion on the image;
- (d) the label shall be displayed by pop up, new tab, new page or inset screen display;
- (e) for magnification of the label on tactile screens, the device conventions for tactile magnification shall apply;
- (f) the label shall cease to be displayed by means of a close option or other standard closing mechanism;
- (g) the alternative text for the graphic, to be displayed on failure to display the label, shall be the energy efficiency class of the product or package in a font size equivalent to that of the price.
- (5)The appropriate product fiche made available by suppliers in accordance with Article 3 shall be shown on the display mechanism in proximity to the price of the product or package. The size shall be such that the product fiche is clearly visible and legible. The product fiche may be displayed using a nested display, in which case the link used for accessing the fiche shall clearly and legibly indicate ‘Product fiche’. If nested display is used, the product fiche shall appear on the first mouse click, mouse roll-over or tactile screen expansion on the link.
[^E0001]: OJ L 334, 17.12.2010, p. 17.
[^E0002]: See page 1 of this Official Journal.
[^E0003]: OJ L 315, 14.11.2012, p. 1.
[^E0004]: OJ L 27, 30.1.2010, p. 1.
Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.
This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence.
EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.