Commission Regulation (EU) 2017/2400 of 12 December 2017 implementing Regulation (EC) No 595/2009 of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles and amending Directive 2007/46/EC of the European Parliament and of the Council and Commission Regulation (EU) No 582/2011 (Text with EEA relevance. )

Type Regulation
Publication 2017-12-29
Last updated 2026-01-01
State In force
Department European Commission, GROW
Source EUR-Lex
articles 27
Reform history JSON API
  • Passive components that may affect the fuel consumption of the FCS shall either be part of the FCS UUT or be fitted inside the test setup to ensure a comparable vehicle-like operation situation.
  • The FCS UUT shall be set up on the test bed in accordance with the requirements set out in Table 9 and points 7.2.2 and 7.2.3. The type of FCS shall be determined dependent on the actual configuration of the FCS UUT on the test bed and one of the type identifiers ‘A’, ‘B’, ‘C’ or ‘D’ shall be assigned in accordance with the requirements set out in Table 9.
  • 7.2.2Fuel Cell Systems without Power Conditioning Sub-system
  • If PCS is not included, the correction methods laid down in point 7.5 shall be applied to account for the impact of the power loss due to the PCS efficiency.
  • 7.2.3Fuel Cell Systems excluding power consuming balance of plant components
  • The correction methods laid down in point 7.5 shall be applied to account for the power consuming components that are mandatory for the operation of the FCS and are not included in the UUT. All excluded power consuming components shall be listed and their power uptake documented in the information document set out in Appendix 7.

Table 9

Definition of different FCS-variants (Types A to D) for certification

Sub-System Component Part of FCS Part of FCS Part of FCS Part of FCS Fitted for certification test Fitted for certification test Fitted for certification test Fitted for certification test
Sub-System Component Type_A Type_B Type_C Type_D Type_A Type_B Type_C Type_D
APS (Air Processing Sub-system) Inlet particle filter No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
APS (Air Processing Sub-system) Inlet manifold No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
APS (Air Processing Sub-system) Intake air charging equipment (e.g. el. turbocharger or compressor) Yes Yes Yes Yes Yes Yes Yes Yes
APS (Air Processing Sub-system) Air flow meter [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
APS (Air Processing Sub-system) Air inlet duct work No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
APS (Air Processing Sub-system) Inlet silencer [^E0083] No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
APS (Air Processing Sub-system) Charge air cooler [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
APS (Air Processing Sub-system) Humidification [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
TMS All coolant pump(s) Yes Yes No, or partly No, or partly Yes Yes Yes, else test cell equipment [^E0081] [^E0082] [^E0085] ) Yes, else test cell equipment [^E0081] [^E0082] [^E0085] )
TMS Radiator No No No No Test cell equipment [^E0082] Test cell equipment [^E0082] Test cell equipment [^E0082] Test cell equipment [^E0082]
TMS Ion-Exchanger [^E0083] [^E0086] Yes Yes Yes Yes Yes, or test cell equipment [^E0082] [^E0083] Yes, or test cell equipment [^E0082] [^E0083] Yes, or test cell equipment [^E0082] [^E0083] Yes, or test cell equipment [^E0082] [^E0083]
TMS Fan No No No No No No No No
WTS Water seperator [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
WTS Drain Valve [^E0083] [^E0086] Yes Yes Yes Yes Yes Yes Yes Yes
WTS Exhaust manifold No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
WTS Connecting pipes No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
WTS Silencer [^E0083] No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
WTS Tail pipe No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
WTS Exhaust H2-Sensor No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
FPS Fuel Supply System (FSS) No No No No Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082] Yes, or test cell equipment [^E0082]
FPS Pressure regulator / Injector Yes Yes Yes Yes Yes Yes Yes Yes
FPS Fuel heat exchanger [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
FPS Active Recirculation device (Compressor/Pump) [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
FPS Passive Recirculation Devise (Injector/Ejector) [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
FPS Filters [^E0083] Yes Yes Yes Yes Yes Yes Yes Yes
FCSS [^E0080] Yes Yes Yes Yes Yes Yes Yes Yes
PDS Electrical components (e.g. cables, switches, relays) [^E0080] Yes Yes Yes Yes Yes [^E0084] Yes [^E0084] Yes [^E0084] Yes [^E0084]
PCS Voltage regulator (DC/DC) and/or converter (DC/AC) Yes No Yes No Yes Test cell equip-ment [^E0081] [^E0082] Yes Test cell equip-ment [^E0081] [^E0082]
fuel cell control sub-system Processing/control unit Yes Yes Yes Yes Yes Yes Yes Yes
fuel cell control sub-system Software of specified version Yes Yes Yes Yes Yes [^E0084] Yes [^E0084] Yes [^E0084] Yes [^E0084]

no further break-down

not part of the certified energy balance, missing BoPC shall be accounted for using the methods laid down in point 7.5

according to manufacturer specification which shall ensure real world like operation

if applicable/mounted on FCS respectively vehicle

only adaptions are allowed to enable standalone operation

[^E0085]: (5)

integration of items is optional

may be part of either TMS or WTS

  • 7.2.4Description of specific BoPCs
  • The TMS and the cooling sub-system may consist of multiple coolant circuits. All those circuits may be divided into an inner and outer part.
  • 7.2.4.1Inner part of the cooling circuit
- Inner part of the cooling circuit consists of all parts of the cooling circuit that are integrated into the FCS and are part of the TMS of the UUT.
- 7.2.4.2Outer part of the cooling circuit
  • All parts of the cooling sub-system that are not part of the UUT are referred to as the outer cooling sub-system, including the heat exchangers that are integrated into the vehicle chassis and might vary dependent on the vehicle type or other parts that are not part of the UUT.

7.3.   Test procedure

  • 7.3.1Purpose
  • The purpose of the certification test procedure is to validate performance and capabilities declared by the manufacturer of the FCS, and to measure the fuel consumption / hydrogen mass flow under certain well-defined operating conditions. The aim is to generate reproducible data, suitable as input data for the simulation tool to enable the fuel consumption prediction of the certified vehicle component FCS.
  • 7.3.2Operation parameters and operating points
  • The parameters set out in Table 10 shall apply for the purposes of the certification test.

Table 10

Operation Parameters and Operating Points

Name / Description Mandatory: Y/N Unit
SCOP Y kW
relative transition slope for set-point ramp-up (RTS-UP) The manufacturer may specify a value for RTS-UP. If no value is specified the default value in accordance with point 7.3.4.6 shall be used. N s-1
relative transition slope for set-point ramp-down (RTS-DOWN) The manufacturer may specify a value for RTS-DOWN. If no value is specified the default value in accordance with point 7.3.4.6 shall be used. N s-1
operating points: #01 .. #nop OP01, lower electrical power-output of FCS at OP #01, OPnop upper operating point. One row in the table per point. To indicate if OPxx is tested during ramp-up or ramp-down, an additional suffix in form of one character shall be added in the information documents, which shall be letter ‘a’ for ascending operating points, and letter ‘d’ for descending operating points. Y kW
FCS Type A/C (PCS part of UUT): Lower voltage level of PCS output UPCS, out, lower at which the FCS can be operated at OPnop without current limitation. FCS Type B/D (PCS not part of UUT): UPCS, lower is a DC/DC-requirement specification provided by the manufacturer. The test cell DC/DC shall meet this requirement. Y V
FCS Type A/C (PCS part of UUT): Upper voltage level of PCS output UPCS, out, upper at which the FCS can be operated at OPnop. FCS Type B/D (PCS not part of UUT): UPCS, upper is a DC/DC-requirement specification provided by the manufacturer. The test cell DC/DC shall meet this requirement. Y V
  • 7.3.3Methodology
  • The certification test procedure aims to record static data on a stabilized FCS at a certain number of different operating points. Each operating point shall be specified by its set-point for the electrical FCS power output.
  • During the certification, the FCS shall be operated in its standard operation conditions, as documented by the manufacturer in accordance with Appendix 7.
  • The voltage level at the interface between the PCS and the external electric components shall be determined by the lower and upper voltage level as specified in Table 10 to:
  • UPCS, out = 0,5 * (UPCS, out, upper + UPCS, out, lower)
  • In case the PCS is not included in the UUT, UPCS, upper and UPCS, lower shall be derived from the requirement specifications for the DC/DC converter as provided by the manufacturer.
  • The manufacturer shall declare in accordance with Appendix 7 realistic boundary conditions for normal operation of the FCS for in-vehicle usage.
  • 7.3.4Test procedure description
  • The entire test procedure shall be performed without interruption and the entire test shall be recorded.
  • The manufacturer shall specify the operating point (OP) with the lowest (OP01) and highest (OPnop) electrical FCS power output to be measured as certification test range. That range shall cover the whole span for real world operation in vehicle application.
  • 7.3.4.1Definition of operating points
  • The FCS shall be tested on a defined number of OPs, nop, which shall be equal or greater than 12.
  • The OP with the lowest (OP01) and highest (OPnop) electrical FCS power output shall be measured mandatorily.
  • The remaining number of OP shall be distributed within the certification test range. The distribution of OPs does not need to be equidistant but shall enable a good interpolation of the fuel consumption over the whole certification test range. In regions of elevated non-linear relationship between FCS power output and fuel consumption a smaller step size between set-points is allowed.
  • The naming convention of the operation set-points shall be defined as:
P@OP01 : target electrical FCS power output at OP01
--- --- ---
P@OPxx : target electrical FCS power output at any OP between lowest and highest with the identifier xx running from 02 to (nop -1)
| | | |

| --- | --- | --- | | P@OPnop | : | target electrical FCS power output at OPnop |

- The maximum step size between two adjacent OPs, Step-sizemax, shall be defined in accordance with the following equation:
  • Step-sizemax < 0,20 * (P@OPnop – P@OP01)
  • 7.3.4.2Conditioning phase
  • Prior to the actual test the system shall be operated at least 60 minutes at a SCOP. That set-point (electrical FCS power output target value) shall lie between 40 % and 60 % of the upper operating point for certification, OPnop, and shall be defined by the manufacturer.
  • 7.3.4.3Sequence of operating points
- The series shall start from OP01 and shall be continued in ascending order up to OPnop and then back again to the lowest OP in descending order. The entire duration is dependent on the stabilization time at the individual OPs.
- Figure 3 depicts the whole test sequence in a schematic manner.

Figure 3

Sequence of OP

Image omitted; see official source

  • 7.3.4.4Steps to be performed at each operating point
  • In order to determine the fuel consumption at each OP in a reproducible manner, a sufficient stabilization time at each OP shall be defined by the manufacturer to achieve adequate stability of the system. The stabilization time shall be defined as individual value for each OP to be measured and shall be between tstab,min = 300 - 1 s and tstab,max = 1 800 + 1 s. Both stabilization times for the same OP in the ascending and descending part shall be within a tolerance of 2 seconds. The stabilization time for a measured OP shall start immediately after the ramp from the previous setpoint is completed. The analysis time is required to gain average values avoiding measurement noises and other instationary effects. Therefore, the analysis time shall be set to tanlys = 180 ± 1 s and shall start after the stabilization time. The measured values within that time span shall fulfil the stability criteria set out in point 7.3.4.5 unless the maximum stabilization time of tstab,max = 1 800 + 1 s is applied. After the analysis time, the standby time used for a proper separation from the next load point shall follow and the duration shall be defined as tstb = 10 ± 1 s.
  • Figure 4 depicts the steps to be performed at each OP.

Figure 4

Steps to be performed at each OP

Image omitted; see official source

- 7.3.4.5Stability Criteria
To determine the degree of steadiness of the fuel consumption, metered by means of a test cell sensor at the fuel inlet of the FCS (

Image omitted; see official source

FPS as specified in Figure 5), a least squares linear regression shall be performed, the independent variable being the time and the dependent variable being the fuel flow, in accordance with points 7.3.6.1 and 7.3.6.2. Based on the regression analysis, the following two stability indicators shall be calculated in accordance with point 7.3.6.3:

  • (a) absolute value of the relative slope of the estimate (ARS), which represents the slope;
  • (b) relative error of estimate (REE), which represents the degree of fluctuations of the monitored item.
  • The values for the stability criteria shall be calculated in accordance with point 7.3.6.3. The OP shall be considered as stable if both indicators are below a specific threshold value within the defined analysis time frame. The threshold values for both stabilization indicators ARS and REE shall be calculated in accordance with the threshold values set out in Table 11. For the calculation of the REE, the normalized set power at any OP compared to the highest OP shall be defined as:

Image omitted; see official source

Table 11

Threshold values

Indicator: Threshold Value:
ARS 7,0E-5 sE-1
REE Image omitted; see official source
  • In case the proof of stability at any OP fails, the test shall be repeated with an enlarged or the maximum stabilization time in accordance with point 7.3.4.4.
  • 7.3.4.6Transition slope between two operating points
  • The transition from one set-point to the next shall be executed with a moderate slope. Suitable slopes for up- and down-ramping of the set-point shall be specified by the manufacturer. The objective shall be to set a slope that facilitates a quick stabilization on the subsequent operating point. No restrictions shall apply to the value of the transition slope or to the shape of that slope. In case no transition slope is specified by the manufacturer, the RTS shall be set to +0,002 ±0,0004 s-1 during ramp-up and 0,002  ±0,0004 s-1during ramp-down.

Image omitted; see official source

  • where:
P el : electrical DC power output of the FCS
--- --- ---
Image omitted; see official source : slope of the transition of one operating point Pel, 1 at time t1 to a following operating point Pel, 2 at time t2. Where the transition time Image omitted; see official source is small enough to neglect the effects of non-linearity
--- --- ---
P@OPn op : target electrical FCS power output at highest OP
  • 7.3.4.7Calculation of measured fuel consumption and power output
  • The electric power output and the corresponding hydrogen consumption rate of the UUT at each individual OP shall be calculated as the arithmetic mean over the analysis time tanlys defined in accordance with point 7.3.4.4. The calculation of the arithmetic means shall be done as follows:

Image omitted; see official source

  • and

Image omitted; see official source

  • where:
P FCS, avg, p : arithmetic mean over n recorded values within tanlys of the electrical power output P FCS, i, p in kW
--- --- ---
P FCS, i, p : recorded value of electrical power output with index number i in kW.
  • This power output is metered UUT-type dependent after the PDS (sensor position: P_el, PDS, as depicted in Figure 5) or PCS (sensor position: P_el, PCS as set out in point 7.4, figure 5)
Image omitted; see official source : arithmetic mean over n recorded values within tanlys of the fuel flow Image omitted; see official source in g/h
--- --- ---
Image omitted; see official source : recorded value of fuel flow with index number i in g/h
--- --- ---
i : Index of individual recorded data point 1 to n
--- --- ---
p : Index for ascending (a) or descending (d) path (omitted for OPnop)
--- --- ---
n: : number of recorded values during the averaging period tanlys defined in accordance with point 7.3.4.4.
  • Subsequently, one resulting arithmetic mean for both values P FCS, avg and

Image omitted; see official source for each individual OP below OPnop shall be calculated as the arithmetic mean of the averaged values from the ascending and descending part in accordance with the following equations:

Image omitted; see official source

  • and

Image omitted; see official source

  • where:
P FCS, avg, a : arithmetic mean of the electrical power output during the ascending path determined in accordance with the preceding paragraph in kW
--- --- ---
P FCS, avg, d : arithmetic mean of the electrical power output during the descending path determined in accordance with the preceding paragraph in kW
--- --- ---
Image omitted; see official source : arithmetic mean of the fuel flow during the ascending path determined in accordance with the preceding paragraph in g/h
--- --- ---
Image omitted; see official source : arithmetic mean of the fuel flow during the descending path determined in accordance with the preceding paragraph in g/h.
  • For the OPnop (upper OP), this averaging step is not applicable since for this OP only one single measurement exists.
  • 7.3.4.8Correction of the FCS power output to reference conditions
  • The measured FCS power output PFCS shall be corrected in accordance with the following equation:

Image omitted; see official source

  • with:

Image omitted; see official source

  • where:
Image omitted; see official source : Electrical power output of FCS at reference conditions in kW
--- --- ---
PFCS,avg : Electrical power output of FCS in accordance with point 7.3.4.7 in kW
| | | |

| --- | --- | --- | | Image omitted; see official source | : | Fuel flow in accordance with point 7.3.4.7 in g/h |

| | | |

| --- | --- | --- | | NCVstd,H2 | : | Standard net calorific value of hydrogen in accordance with point 5.3.3.1 in MJ/kg | | | | | | --- | --- | --- | | p | : | Pressure at reference conditions with the numerical value of 0,975 bar | | | | | | --- | --- | --- | | pin | : | Pressure of intake air to the APS of the UUT (p_A,APS as specified in Figure 5) in bar. The value shall be calculated as the arithmetic mean over the respective analysis time tanlys defined in accordance with point 7.3.4.4 and the resulting value shall be subsequently averaged over the ascending and descending part (except for OPnop*) as prescribed for the signal of fuel consumption in accordance with point 7.3.4.7. | | | | | | --- | --- | --- | | kload | : | Gradient of efficiency determined in accordance with point 7.3.4.8.1 in bar-1. |

- 7.3.4.8.1Gradient of efficiency kload
- The value of normalized power shall be determined by dividing the value of PFCS,avg of a specific OP by the value of PFCS,avg for OPnop, both derived in accordance with point 7.3.4.7.
  • Based on the value of normalized power of a specific OP, the value of kload shall be determined from the corresponding data in Table 12 by means of linear interpolation between the two adjacent data points. In case the value of normalized power is lower than 0,1, the value of kload defined at 0,1 normalized power shall be used.

Table 12

Parameter kload as function of normalized power

Normalized power [-] kload
0,1 0,3730
0,2 0,1485
0,5 0,0745
0,8 0,0855
1,0 0,1115
  • 7.3.5Test Conditions
  • The ambient conditions in the test cell shall fulfil the minimum and maximum criteria set out in Table 13.

Table 13

Ambient and media condition limits during certification test

min value max value
Ambient pressure 90,0 kPa 102,0 kPa
Ambient temperature 288,0 K 298,0 K
Oxidant (air) inlet pressure 90,0 kPa 102,0 kPa
Oxidant (air) inlet temperature 288,0 K 303,0 K
Relative Humidity, Oxidant (air) supply 45,0 % 80,0 %
  • 7.3.6Statistics
  • 7.3.6.1Mean value and standard deviation
  • The arithmetic mean value shall be calculated as follows:

Image omitted; see official source

  • The standard deviation shall be calculated as follows:

Image omitted; see official source

  • 7.3.6.2Regression analysis
  • The slope of the regression shall be calculated as follows:

Image omitted; see official source

  • The y intercept of the regression shall be calculated as follows:
  • The standard error of estimate shall be calculated as follows:
- 7.3.6.3Stability criteria
  • The ARS shall be calculated as follows:
  • The REE value shall be calculated as follows:

Image omitted; see official source

7.4.   Certification test documentation

The relevant data for test reproducibility shall be documented in the information document set out in Appendix 7. The position of different sensors used for testing shall be defined in accordance with the schematic sketch of a representative FCS set out in figure 5.

Figure 5

Schematic sketch of a representative FCS including the position of relevant sensors

Image omitted; see official source

7.5   Calculation of effective electrical power output

The electrical power output of fuel cell system at reference conditions,

Image omitted; see official source

, determined in accordance with point 7.3.4.8 shall be corrected for the following configurations:

  • (a) PCS not being part of the FCS installed for the certification test;
  • (b) power consuming balance of plant components not installed for the certification test at all or not installed within the UUT or being externally powered by the test bed infrastructure during the certification test.
  • 7.5.1Recording of additional values
  • For each coolant pump not installed for the certification test at all or not installed within the UUT the following values shall be recorded separately:
  • (V C,TMS,in) volume flow of the coolant upstream of the TMS;
  • pC,TMS,in pressure of the coolant upstream of the TMS;
  • pC,TMS,out pressure of the coolant downstream of the TMS.
  • For each power consuming balance of plant component being externally powered by the test bed infrastructure during the certification test the electrical power uptake, Pel,AUX, shall be recorded separately.
  • In accordance with point 3.2.2 the volume flow and the electrical power uptake shall have a positive algebraic sign.
  • All recorded values shall be averaged for each individual operating point of the FCS measured in accordance with the method set out in point 7.3.4.7 by applying the same specific averaging period tanlys in accordance with point 7.3.4.4.
  • 7.5.2Equations for corrections performed
  • All following equations shall be evaluated for each individual operating point of the FCS measured in accordance with the method set out in point 7.3.4.7.
  • In case the PCS not being part of the FCS installed for the certification test, the measured electrical power output at the location PDS in accordance with the schematic sketch of a representative FCS set out in figure 5 shall be corrected for the losses of a generic PCS in accordance with the following equation:
  • P*el,PCS =

Image omitted; see official source ×etaDC/DC

  • where:
  • P*el,PCS electrical power output at the location PCS in accordance with Figure 5 at reference conditions in kW
  • P FCS,PDS* electrical power output of fuel cell system at the location PDS in accordance with the schematic sketch of a representative FCS set out in figure 5 at reference conditions determined in accordance with point 7.3.4.8 in kW
  • etaDC/DC generic efficiency factor of DC/DC converter shall be 0.975
  • For each coolant pump not installed for the certification test at all or not installed within the UUT the electrical power uptake shall be calculated in accordance with the following equation:
  • Pel,Cool = (pC,TMS,in - pC,TMS,out) ×

Image omitted; see official source C,TMS,in / etaWP,hyd / etaWP,EM

  • where:
  • Pel,Cool electrical power uptake of the coolant pump in kW
  • pC,TMS,in pressure of the coolant upstream of the TMS in kPa
  • pC,TMS,out pressure of the coolant downstream of the TMS in kPa
  • etaWP,hyd generic hydraulic efficiency factor of pump shall be 0,8
  • etaWP,EM generic efficiency factor of electric pump drive shall be 0,8.
  • The final effective electrical power output of FCS used as input to the simulation tool taking all components consuming additional electric power into account shall be calculated in accordance with the following equation:
  • Pel,FCS,net = Pel,PCS +

Image omitted; see official source +

Image omitted; see official source +

Image omitted; see official source +

Image omitted; see official source

  • where:
  • P*el,FCS,net effective electrical power output of FCS (used as input to the simulation tool) at reference conditions in kW
  • P*el,PCS electrical power output at the location PCS in accordance with Figure 5 at reference conditions in kW
  • Pel,AUX electrical power uptake of balance of plant component not installed for the certification test at all or not installed within the UUT or being externally powered by the test bed infrastructure during the certification test in kW

where the following differentiation shall be applied:

  • Pel,AUX,i all components connected to the FCS either at the location PDS in accordance with Figure 5 or via a separate DC/DC converter; where i = 1, 2, 3, … maximum number n of such components to be considered

- Pel,AUX,j all components connected to the FCS either at the location PCS in accordance with Figure 5 or without a separate DC/DC converter; where j = 1, 2, 3, … maximum number o of such components to be considered

- Pel,Cool electrical power uptake of the coolant pump in kW

where the following differentiation shall be applied:

- Pel,Cool,k all coolant pumps connected to the FCS either at the location PDS in accordance with Figure 5 or via a separate DC/DC converter; where k = 1, 2, 3, … maximum number p of such components to be considered
  • Pel,Cool,l all coolant pumps connected to the FCS either at the location PCS in accordance with Figure 5 or without a separate DC/DC converter; where l = 1, 2, 3, … maximum number q of such components to be considered
  • etaDC/DC generic efficiency factor of DC/DC converter shall be 0,975.
  • 7.5.3Input to the simulation tool
  • The values of effective electrical power output P* el,FCS,net determined in accordance with point 7.5.2 multiplied by -1 and absolute values of the fuel flow determined in accordance with point 7.3.4.7 shall be used as input to the simulation tool.

Appendix 1

MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM

Maximum format: A4 (210 × 297 mm)

CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF AN ELECTRIC MACHINE SYSTEM / IEPC / IHPC Type 1 / BATTERY SYSTEM/ CAPACITOR SYSTEM

Administration stamp

Communication concerning:

  • — granting (1)
- — extension(1)
  • — refusal(1)
  • — withdrawal(1)

of a certificate on CO2 emission and fuel consumption related properties of an electric machine system / IEPC / IHPC Type 1 / battery system / capacitor system in accordance with Commission Regulation (EU) 2017/2400.

Commission Regulation (EU) 2017/2400 as last amended by ……………..

Certification number:

Hash:

Reason for extension:

SECTION I

- 0.1.Make (trade name of manufacturer):
  • 0.2.Type:
  • 0.3.Means of identification of type
  • 0.3.1.Location of the certification marking:
  • 0.3.2.Method of affixing certification marking:
  • 0.5.Name and address of manufacturer:
  • 0.6.Name(s) and address(es) of assembly plant(s):
  • 0.7.Name and address of the manufacturer's representative (if any)

SECTION II

  • 1.Additional information (where applicable): see Addendum
  • 2.Approval authority responsible for carrying out the tests:

- 3.Date of test report:

- 4.Number of test report:

  • 5.Remarks (if any): see Addendum
  • 6.Place:
  • 7.Date:
  • 8.Signature:

Attachments:

Information package. Test report.

Appendix 2

Information Document for an electric machine system

  • Information document no.: Issue:

Date of issue:

Date of Amendment:

pursuant to …

Electric machine system type / family (if applicable):

…

  • 0.GENERAL
  • 0.1.Name and address of manufacturer
  • 0.2.Make (trade name of manufacturer):
- 0.3.Electric machine system type:
- 0.4.Electric machine system family:
  • 0.5.Electric machine system type as separate technical unit / Electric machine system family as separate technical unit
  • 0.6.Commercial name(s) (if available):
  • 0.7.Means of identification of model, if marked on the Electric machine system:
  • 0.8.In the case of components and separate technical units, location and method of affixing of the EC approval mark:
  • 0.9.Name(s) and address(es) of assembly plant(s):
  • 0.10.Name and address of the manufacturer's representative:

PART 1

ESSENTIAL CHARACTERISTICS OF THE (PARENT) ELECTRIC MACHINE SYSTEM AND THE ELECTRIC MACHINE SYSTEM TYPES WITHIN AN ELECTRIC MACHINE SYSTEM FAMILY

|Parent EMS |Family members |Family members |Family members |Family members |Family members
|or EMS type | | | | |
| | | #1 | #2 | #3 |
  • 1.General
  • 1.1.Test voltage(s): V
  • 1.2.Basic motor rotational speed: 1/min
  • 1.3.Motor output shaft maximum speed: 1/min
  • 1.4.(or by default) reducer/gearbox outlet shaft speed: 1/min
  • 1.5.Maximum power speed: 1/min
  • 1.6.Maximum power: kW
  • 1.7.Maximum torque speed: 1/min
  • 1.8.Maximum torque: Nm
  • 1.9.Maximum 30 minutes power: kW
  • 2.Electric machine
  • 2.1.Working principle
  • 2.1.1.Direct current (DC)/alternating current (AC):
  • 2.1.2.Number of phases:
  • 2.1.3.Excitation / separate / series / compound:
  • 2.1.4.Synchron / asynchron:
  • 2.1.5.Rotor coiled / with permanent magnets / with housing:
  • 2.1.6.Number of poles of the motor:
  • 2.2.Rotational inertia: kgm2
  • 3.Power controller
  • 3.1.Make:
  • 3.2.Type:
  • 3.3.Working principle:
  • 3.4.Control principle: vectorial / open loop / closed / other (t.b.s.):
  • 3.5.Maximum effective current supplied to the motor: A
  • 3.6.For maximum duration of: s
  • 3.7.DC voltage range used (from / to): V
  • 3.8.DC/DC converter is part of the electric machine system in accordance with paragraph 4.1 of this Annex (yes/no):
  • 4.Cooling system
  • 4.1.Motor (liquid / air / other t.b.s.):
  • 4.2.Controller (liquid / air / other t.b.s.):
  • 4.3.Description of the system:
  • 4.4.Principle drawing(s):
  • 4.5.Temperature boundary limits (min/max): K
  • 4.6.At reference position:
  • 4.7.Flow rates (min/max): ltr/min
  • 5.Documented values from component testing
  • 5.1.Efficiency figures for CoP ([^E0087]):
- 5.2.Cooling system (declaration for each cooling circuit):
  • 5.2.1.maximum coolant mass flow or volume flow or maximum inlet pressure:
- 5.2.2.maximum coolant temperatures:
  • 5.2.3.maximum available cooling power:

- 5.2.4.Recorded average values for each test run

- 5.2.4.1.coolant volume flow or mass flow:

  • 5.2.4.2.coolant temperature at the inlet of the cooling circuit:
  • 5.2.4.3.coolant temperature at the inlet and outlet of the test bed heat exchanger on the side of the EMS:

LIST OF ATTACHMENTS

No.: Description: Date of issue:
1 Information on EMS test conditions …
2 …

Attachment 1 to Electric machine system information document

Information on test conditions (if applicable)
1.1 …

Appendix 3

Information Document for an IEPC

  • Information document no.: Issue:

Date of issue:

Date of Amendment:

pursuant to …

IEPC type / family (if applicable):

…

  • 0.GENERAL
  • 0.1.Name and address of manufacturer
  • 0.2.Make (trade name of manufacturer):
- 0.3.IEPC type:
- 0.4.IEPC family:
  • 0.5.IEPC type as separate technical unit / IEPC family as separate technical unit
  • 0.6.Commercial name(s) (if available):
  • 0.7.Means of identification of model, if marked on the IEPC:
  • 0.8.In the case of components and separate technical units, location and method of affixing of the EC approval mark:
  • 0.9.Name(s) and address(es) of assembly plant(s):
  • 0.10.Name and address of the manufacturer's representative:

PART 1

ESSENTIAL CHARACTERISTICS OF THE (PARENT) IEPC AND THE IEPC TYPES WITHIN AN IEPC FAMILY

|Parent IEPC |Family members |Family members |Family members |Family members |Family members
|or IEPC type | | | | |
| | | #1 | #2 | #3 |
  • 1.General
  • 1.1.Test voltage(s): V
  • 1.2.Basic motor rotational speed: 1/min
  • 1.3.Motor output shaft maximum speed: 1/min
  • 1.4.(or by default) reducer/gearbox outlet shaft speed: 1/min
  • 1.5.Maximum power speed: 1/min
  • 1.6.Maximum power: kW
  • 1.7.Maximum torque speed: 1/min
  • 1.8.Maximum torque: Nm
  • 1.9.Maximum 30 minutes power: kW
  • 1.10.Number of electric machines:
  • 2.Electric machine (for each electric machine):
  • 2.1.Electric machine ID:
  • 2.2.Working principle
  • 2.2.1.Direct current (DC)/alternating current (AC):
  • 2.2.2.Number of phases:
  • 2.2.3.Excitation / separate / series / compound:
  • 2.2.4.Synchron / asynchron:
  • 2.2.5.Rotor coiled / with permanent magnets / with housing:
  • 2.2.6.Number of poles of the motor:
  • 2.3.Rotational inertia: kgm2
  • 3.Power controller (for each power controller):
  • 3.1.Corresponding electric machine ID:
  • 3.2.Make:
  • 3.3.Type:
  • 3.4.Working principle:
  • 3.5.Control principle: vectorial / open loop / closed / other (t.b.s.):
  • 3.6.Maximum effective current supplied to the motor: A
  • 3.7.For maximum duration of: s
  • 3.8.DC voltage range used (from / to): V
  • 3.9.DC/DC converter is part of the electric machine system in accordance with paragraph 4.1 of this Annex (yes/no):
  • 4.Cooling system
  • 4.1.Motor (liquid / air / other t.b.s.):
  • 4.2.Controller (liquid / air / other t.b.s.):
  • 4.3.Description of the system:
  • 4.4.Principle drawing(s):
  • 4.5.Temperature boundary limits (min/max): K
  • 4.6.At reference position:
  • 4.7.Flow rates (min/max): g/min or ltr/min
  • 5.Gearbox
  • 5.1.Gear ratio, gearscheme and powerflow:
  • 5.2.Center distance for countershaft transmissions:
  • 5.3.Type of bearings at corresponding positions (if fitted):
  • 5.4.Type of shift elements (tooth clutches, including synchronisers or friction clutches) at corresponding positions (where fitted):
  • 5.5.Total number of forward gears:
  • 5.6.Number of tooth shift clutches:
  • 5.7.Number of synchronisers:
  • 5.8.Number of friction clutch plates (except for single dry clutch with 1 or 2 plates):
  • 5.9.Outer diameter of friction clutch plates (except for single dry clutch with 1 or 2 plates):
  • 5.10.Surface roughness of the teeth (incl. drawings):
  • 5.11.Number of dynamic shaft seals:
  • 5.12.Oil flow for lubrication and cooling per transmission input shaft revolution
  • 5.13.Oil viscosity at 100 C (± 10 %):
  • 5.14.System pressure for hydraulically controlled gearboxes:
  • 5.15.Specified oil level in reference to central axis and in accordance with the drawing specification (based on average value between lower and upper tolerance) in static or running condition. The oil level is considered as equal if all rotating transmission parts (except for the oil pump and the drive thereof) are located above the specified oil level:
  • 5.16.Specified oil level (± 1mm):
  • 5.17.Gear ratios [-] and maximum input torque [Nm], maximum input power (kW) and maximum input speed [rpm] (for each forward gear):
  • 6.Differential
  • 6.1.Gear ratio:
  • 6.2.Principle technical specifications:
  • 6.3.Principle drawings:
  • 6.4.Oil volume:
  • 6.5.Oil level:
  • 6.6.Oil specification:
  • 6.7.Bearing type (type, quantity, inner diameter, outer diameter, width and drawing):
  • 6.8.Seal type (main diameter, lip quantity):
  • 6.9.Wheel ends (drawing):
  • 6.9.1.Bearing type (type, quantity, inner diameter, outer diameter, width and drawing):
  • 6.9.2.Seal type (main diameter, lip quantity):
  • 6.9.3.Grease type:
  • 6.10.Number of planetary / spur gears for differential:
  • 6.11.Smallest width of planetary/ spur gears for differential:
  • 7.Documented values from component testing
  • 7.1.Efficiency figures for CoP (*):
- 7.2.Cooling system (declaration for each cooling circuit):
  • 7.2.1.maximum coolant mass flow or volume flow or maximum inlet pressure:
- 7.2.2.maximum coolant temperatures:
  • 7.2.3.maximum available cooling power:
  • 7.2.4.Recorded average values for each test run
  • 7.2.4.1.coolant volume flow or mass flow:

- 7.2.4.2.coolant temperature at the inlet of the cooling circuit:

- 7.2.4.3.coolant temperature at the inlet and outlet of the test bed heat exchanger on the side of the IEPC:

LIST OF ATTACHMENTS

| | | |

| --- | --- | --- | | No.: | Description: | Date of issue: | | 1 | Information on IEPC test conditions … | | | 2 | … | |

Attachment 1 to IEPC information document

  • 8.Information on test conditions (if applicable)
  • 8.1.Maximum tested input speed [rpm]
  • 8.2.Maximum tested input torque [Nm]

Appendix 4

Information Document for an IHPC Type 1

For IHPCs Type 1 the information document shall consist of the applicable parts of the information document for electric machine systems in accordance with Appendix 2 of this Annex and of the information document for transmissions in accordance with Appendix 2 of Annex VI.

Appendix 5

Information Document for a battery system or a representative battery subsystem type

  • Information document no.: Issue:

Date of issue:

Date of Amendment:

pursuant to …

Battery system or representative battery subsystem type:

…

  • 0.GENERAL
  • 0.1.Name and address of manufacturer
  • 0.2.Make (trade name of manufacturer):
- 0.3.Battery system type:
- 0.4.-
- 0.5.Battery system type as separate technical unit
  • 0.6.Commercial name(s) (if available):
  • 0.7.Means of identification of model, if marked on the Battery system:
  • 0.8.In the case of components and separate technical units, location and method of affixing of the EC approval mark:
  • 0.9.Name(s) and address(es) of assembly plant(s):
  • 0.10.Name and address of the manufacturer's representative:

PART 1

ESSENTIAL CHARACTERISTICS OF THE BATTERY SYSTEM OR THE REPRESENTATIVE BATTERY SUBSYSTEM TYPE

Battery (sub)system type

  • 1.General
  • 1.1.Complete system or representative subsystem:
  • 1.2.HPBS / HEBS:
  • 1.3.Principle technical specifications:
  • 1.4.Cell chemistry:
  • 1.5.Number of cells in series:
  • 1.6.Number of cells in parallel:
  • 1.7.Representative junction box with fuses and breakers included in tested system (yes/no):
  • 1.8.Representative serial connectors included in the tested system (yes/no):
  • 2.Conditioning system
  • 2.1.Liquid / air / other t.b.s.:
  • 2.2.Description of the system:
  • 2.3.Principle drawing(s):
  • 2.4.Temperature boundary limits (min/max): K
  • 2.5.At reference position:
  • 2.6.Flow rates (min/max): ltr/min
- 3.Documented values from component testing
  • 3.1.Round trip efficiency for CoP (**):
- 3.2.Maximum discharge current for CoP:
  • 3.3.Maximum charge current for CoP:

- 3.4.Testing temperature (target operating temperature declared):

- 3.5.Conditioning system (indicate for each test run performed)

  • 3.5.1.Cooling or heating required:
  • 3.5.2.Maximum available cooling or heating power:

LIST OF ATTACHMENTS

No.: Description: Date of issue:
1 Information on Battery system test conditions …
2 …

Attachment 1 to Battery system information document

Information on test conditions (if applicable)
1.1 …

Appendix 6

Information Document for a capacitor system or a representative capacitor subsystem type

  • Information document no.: Issue:

Date of issue:

Date of Amendment:

pursuant to …

Capacitor system or representative capacitor subsystem type:

…

  • 0.GENERAL
  • 0.1.Name and address of manufacturer
  • 0.2.Make (trade name of manufacturer):
- 0.3.Capacitor system type:
- 0.4.Capacitor system family:
- 0.5.Capacitor system type as separate technical unit / Capacitor system family as separate technical unit
  • 0.6.Commercial name(s) (if available):
  • 0.7.Means of identification of model, if marked on the Capacitor system:
  • 0.8.In the case of components and separate technical units, location and method of affixing of the EC approval mark:
  • 0.9.Name(s) and address(es) of assembly plant(s):
  • 0.10.Name and address of the manufacturer's representative:

PART 1

ESSENTIAL CHARACTERISTICS OF THE CAPACITOR SYSTEM OR THE REPRESENTATIVE CAPACITOR SUBSYSTEM TYPE

Capacitor (sub)system type

  • 1.General
  • 1.1.Complete system or representative subsystem:
  • 1.2.Principle technical specifications:
  • 1.3.Cell technology and specification:
  • 1.4.Number of cells in series:
  • 1.5.Number of cells in parallel:
  • 1.6.Representative junction box with fuses and breakers included in tested system (yes/no):
  • 1.7.Representative serial connectors included in the tested system (yes/no):
  • 2.Conditioning system
  • 2.1.Liquid / air / other t.b.s.:
  • 2.2.Description of the system:
  • 2.3.Principle drawing(s):
- 2.4.Temperature boundary limits (min/max): K
  • 2.5.At reference position:
- 2.6.Flow rates (min/max): ltr/min
  • 3.Documented values from component testing

- 3.1.Testing temperature (target operating temperature declared):

  • 3.2.Conditioning system (indicate for each test run performed)
  • 3.2.1.Cooling or heating required:
  • 3.2.2.Maximum available cooling or heating power:

LIST OF ATTACHMENTS

No.: Description: Date of issue:
1 Information on Capacitor system test conditions …
2 …

Attachment 1 to Capacitor system information document

Information on test conditions (if applicable)
1.1 …

Appendix 7

Information document for FCS

Communication concerning: — granting [^E0088] — extension [^E0088] — refusal [^E0088] — withdrawal [^E0088] Administration stamp

delete if not applicable

of a certificate on CO2 emission and fuel consumption related properties of an electric machine system IEPC / IHPC Type 1 / battery system / capacitor system in accordance / FCS / with Commission Regulation (EU) 2017/2400.

Commission Regulation (EU) 2017/2400 as applicable on [date]

Certification number:

Hash:

Reason for extension:

Information document No: Issue: Date of issue: Date of Amendment:

pursuant to …

FCS type / family (if applicable):
0. GENERAL
0.1. Name and address of manufacturer:
0.2. Make (trade name of manufacturer):
0.3. FCS type:
0.4. FCS family:
0.5. FCS type as separate technical unit / FCS family as separate technical unit:
0.6. Commercial names (if available):
0.7. Means of identification of model, if marked on the FCS:
0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark:
0.9. Names and addresses of assembly plants:
0.10. Name and address of the manufacturer's representative:
PART 1

ESSENTIAL CHARACTERISTICS OF THE (PARENT) FCS AND THE FCS TYPES WITHIN A FCS FAMILY

Parent FCS Family members Family members Family members Family members
or FCS type Family members Family members Family members Family members
#1 #2 #3 …
1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: … 1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: … 1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: … 1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: … 1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: … 1. General: 1.1.  Upper power of FCS (specified upper electric power in real world operation): … kW 1.2.  Weight of FCS (including all parts of UUT): … kg 1.3.  Gross outer dimension of FCS (length, width and height): … mm 1.4.  Uout range at the UUT interface, either PDS, out or PCS, out (min/max): … V 1.5.  Iout range at the UUT interface, either PDS, out or PCS, out (min/max): … A 1.6.  Output voltage range of PCS (min/max) [^E0089]: … V 1.7.  Type of FCS regarding test setup [^E0090] (A, B, C, D): … 2. APS: 2.1.  Air Compressor 2.1.1.  Make(s), type(s) … 2.1.2.  Power uptake in certification test range (min/max) … kW 2.2.  Air humidification device [^E0089] 2.2.1.  Make(s), type(s): … 2.2.2.  Humidity exchange membrane, make(s), type(s): … 3. TMS: 3.1.  Cooling media of inner cooling liquid 3.1.1.  Make(s), type(s) … 3.1.2.  Specific heat capacity @345 K: … J/(kg·K) 3.1.3.  Density @345 K: … kg/l 4. WTS: 4.1.  Deionization unit 4.1.1.  Make(s), type(s) … 4.1.2.  Ion-conductivity cooling media (nominal/max) … mS/cm 5. FPS: 5.1.  Fuel injector or combination of injector/ejector: 5.1.1.  Make(s), type(s): … 5.1.2.  Number of injectors: … 5.2.  Anode recirculation blower [^E0089]… 5.2.1.  Make(s), type(s) [^E0089]: … 6. FCSS: 6.1.  FC Stack(s): 6.1.1.  Make(s), type(s): … 6.1.2.  Number of stacks: … 6.1.3.  Cell number of ejach stack: … 6.1.4.  Cell surface area of each stack: … cm2 6.1.5.  Setpoint of the reference current of the stack: … A 6.1.6.  Reference condition [^E0091], temperature Image omitted; see official source : … K 6.1.7.  Reference condition [^E0091], pressure p A, FCSS, in: … kPa 6.1.8.  Reference condition [^E0091], anode stoichiometry ν fuel… 6.1.9.  Reference condition [^E0091], cathode stoichiometry ν Air… 6.1.10.  Stack voltage at reference condition of each stack: … V 6.1.11.  Make(s), Type(s) of membrane electrode assemblies (MEA): … 7. Power Distribution Sub-System (PDS): 7.1.  Power plug at the interface to FCSS [^E0089] 7.1.1.  Make(s), type(s): … 8. Power Conditioning Sub-System (PCS): 8.1.  DC/DC [^E0089] 8.1.1.  Make(s), type(s): … 8.1.2.  Voltage range inlet / primary side (min/max): … V 8.1.3.  Voltage range inlet / secondary side (min/max): … V 9. Fuel Cell Control Sub-System: 9.1.  Firmware, Version & Build Number: … 9.2.  Control Unit Hardware, Make & Type: …
[^E0089]: (*1)

if applicable

In accordance with point 7.2.1 and Table 9 of this Annex

declared by the manufacturer of the FCSS

LIST OF ATTACHMENTS

| No: | Description: | Date of issue: |

| --- | --- | --- | | 1 | Information on FCS test conditions … | DD-MMM-YYYY | | 2 | Information on operation boundary conditions … | DD-MMM-YYYY | | 3 | Information on FCS certification test results … | DD-MMM-YYYY |

Attachment 1 to FCS information document
Information on FCS test conditions:
value and unit value and unit
Ambient pressure (absolute) XYZ.0 kPa
Ambient temperature XYZ.0 K
Oxidant (Air) inlet temperature XYZ.0 K
Oxidant (Air) inlet pressure (absolute) XYZ.0 kPa
Relative Humidity, oxidant / air supply XY.0 %
Cooling media of inner circuit: Make: __, Type: _____
Density of cooling media of inner circuit @345 K XY.0 kg/l
Specific heat capacity of cooling media in the inner cooling circuit @345 K XYZ.0 J/(kg·K)
SCOP: XYZ.0 kW
Operating point #01 (OP01): XYZ.0 kW
Operating point #02 (OP02): XYZ.0 kW
Operating point #xx (OPxx, OP between OP02 and OPnop): XYZ.0 kW
Operating point #nop (OPnop , highest operating point): XYZ.0 kW
FCS Type A/C (PCS part of UUT): Lower voltage level of PCS output UPCS,out,lower at which the FCS can be operated at OPnop without current limitation. FCS Type B/D (PCS not part of UUT): UPCS, lower is a DC/DC-requirement specification XYZ.0 V
FCS Type A/C (PCS part of UUT): Upper voltage level of PCS output UPCS,out,upper at which the FCS can be operated at OPnop. FCS Type B/D (PCS not part of UUT): UPCS, upper is a DC/DC-requirement specification XYZ.0 V
Optional, operation condition related parameters: Optional, operation condition related parameters: Optional, operation condition related parameters:
relative transition slope for set-point ramp-up (RTS-UP) (it is an approximate value for orientation, the manufacturer may specify a range around this number) XYZ.0 s-1
relative transition slope for set-point ramp-down (RTS-DOWN) (it is an approximate value for orientation, the manufacturer may specify a range around this number) XYZ.0 s-1

Attachment 2 to FCS information document

Boundary conditions for FCS operation in vehicles as declared by the manufacturer:

This table is adopted / completed by the manufacturer according to their operation specification for FCS operation inside a vehicle. The specifications in the following table are mandatory:
OP# parameter lower lower upper upper
01 Ambient Temperature XYZ.0 K XYZ.0 K
… Ambient Temperature XYZ.0 K XYZ.0 K
nop Ambient Temperature XYZ.0 K XYZ.0 K
01 Ambient Temperature Ambient Pressure XYZ.0 Pa XYZ.0 Pa
… XYZ.0 Ambient Pressure Pa XYZ.0 Pa
nop XYZ.0 Ambient Pressure Pa XYZ.0 Pa
01 Ambient Humidity Ambient Pressure XYZ.0 % XYZ.0 %
… Ambient Humidity XYZ.0 % XYZ.0 %
nop Ambient Humidity XYZ.0 % XYZ.0 %
01 Ambient Humidity Cooling Liquid Temperature FCSS Inlet Label according to Figure 5: T_C,in with the additional suffix FCSS XYZ.0 K XYZ.0 K
… XYZ.0 Cooling Liquid Temperature FCSS Inlet Label according to Figure 5: T_C,in with the additional suffix FCSS K XYZ.0 K
nop XYZ.0 Cooling Liquid Temperature FCSS Inlet Label according to Figure 5: T_C,in with the additional suffix FCSS K XYZ.0 K
01 Cooling Liquid Temperature FCSS Outlet Cooling Liquid Temperature FCSS Inlet Label according to Figure 5: T_C,in with the additional suffix FCSS XYZ.0 K XYZ.0 K
… Cooling Liquid Temperature FCSS Outlet XYZ.0 K XYZ.0 K
nop Cooling Liquid Temperature FCSS Outlet XYZ.0 K XYZ.0 K
01 Further boundary conditions for operation inside a vehicle XYZ.0 Unit XYZ.0 Unit
… Further boundary conditions for operation inside a vehicle XYZ.0 Unit XYZ.0 Unit
nop Further boundary conditions for operation inside a vehicle XYZ.0 Unit XYZ.0 Unit

Attachment 3 to FCS information document

Table 1

Information on FCS certification test results in form of arithmetic mean values

| OPXXa: ascending OPXXd: descending | 01: Duration / s | 02: ARS / s-1 | 03: REE / - | 04: SP el. power demand for FCS at the interface PDS/PCS() / kW | 05: SP DC current of FCS at the interface PDS/PCS()/ A | 06: PV el. power output of the FCS at the UUT interface (i.e. either PDS or PCS) / kW | 07: PV DC current at the interface UUT interface (i.e. either PDS or PCS) / A | reserved | 09: PV voltage at the UUT interface (i.e. either PDS or PCS) / V | 10: Mass flow of fuel / g/h | … |

Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.

This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence. EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.